ESSELLO BNC Vertical Phototherapy Machine

Machine Body

ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

BNC Phototherapy Machine(LED PDT Therapy Machine)

Three-color Lighting

ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

Main Parameters

1. Red light: irradiance 120mW/cm2, wavelength 630±10mm

2. Blue light: irradiance 150mW/cm2, wavelength 430±10mm

3. Infrared light: irradiance 270mW/cm2, wavelength 830±10mm

4. When the three lights are started at the same time, the maximum output power: ≥10W

5. Maximum optical power density: 1-20 levels precisely adjustable

6. Control panel: 10.1-inch high-definition true color capacitive touch screen

7. Resolution: 1280*800

8. Timing range 1-60min, continuously adjustable, step distance 1min

Use Low Power Cold Light Source

Avoiding Secondary Photodamage In Phototherapy Beauty Treatment

ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

The BNC spectrometer uses imported low-power cold light source LED, which completely subverts the argon lamp and granular LED lamp beads used in domestic phototherapy instruments. It uses 30-40℃, which is closest to the human body temperature. The light is soft and moderate, which can achieve beauty effects without damaging the skin's epidermal cell tissue. There is no pressure to use it without an eye mask.ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

It uses 264 imported lamp beads, with uniform light output and unique light energy mode. Through photochemical action, it can enhance microcirculation, promote metabolism, kill bacteria, and promote blood circulation. It also stimulates collagen production, penetrates deep skin tissue, and stimulates the lymphatic and nervous systems to stimulate the immune system, relax and repair allergic skin.

Operating Interface

ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

Multi-effect Function Introduction

Assists in wrinkle reduction

Promote the absorption of skin care products

Calming, soothing, anti-inflammatory and sterilizing

Stimulate collagen regeneration

Enhance skin immunity

Sensitive skin regeneration management

Enhance microcirculation, promote metabolism, promote blood circulation, stimulate the lymphatic and nervous systems, stimulate the immune system, relax and repair allergic skin

Qualification & Certificate

ESSELLO BNC Vertical Spectrometer (Phototherapy Device) - Guangzhou Muning Biotechnology Co., Ltd.

Precautions

Operation Taboos

1. Pregnant women, people with heart disease or arrhythmia, especially those with pacemakers, are prohibited from doing this.

2. It is forbidden for patients with cancer, major surgery or diabetes;

3. People with epilepsy or severe hypertension are prohibited from doing this;

4. People who are allergic or have serious skin wounds should not do this for the time being;

5. Be careful if you have any metal in your body or gold implants on your face;

6. People who have undergone facial surgery can only use this product three months after surgery.

Safety Precautions

1. Make sure to plug it into a 220-230V, 50/60Hz power socket;

2. Do not touch the power plug casually after plugging in, and do not pull the power cord hard;

3. Do not touch the power cord with wet hands; the power cord must be unplugged when moving this device;

4. Do not impact the instrument or the surrounding area of the power supply with force;

5. When the power plug is dirty, clean it immediately and check if there is any foreign matter before connecting it to the socket.

6. Do not touch the instrument with metal, as it may cause fire or electric shock.

7. Use the instrument properly each time, do not use the instrument for a long time at high temperature; do not place heating equipment near the instrument;

8. Do not disassemble the power socket of the instrument at will after the instrument is started, otherwise it will cause malfunction;

9. If the instrument emits smoke or odor during use, unplug the power cord and consult after-sales service;

Operation Notes

1. Please read the instruction manual carefully and follow the instructions. If the instrument is not used for a long time, please unplug the power supply.

2. You must consult an expert or receive professional training before using the instrument;

3. When using the instrument, first adjust the intensity to the lowest level, then gradually adjust to the appropriate intensity;

4. Each use time should not exceed 30 minutes, and you need to pause for 10 minutes after work before using it again;

5. During operation, guests are not allowed to wear any metal accessories or contact lenses;

6. After using the instrument, clean it with cotton cloth and cotton swab;

7. If any abnormal condition occurs to the patient while using the instrument, please stop the operation immediately and consult an expert;

8. If the instrument has any abnormality, please confirm the instruction manual again before operating; if the abnormality is not resolved, do not disassemble the instrument yourself, but contact after-sales service for consultation.